Total Energy Capacity [kWh]:
5 kWh
80% DoD Energy [kWh]
4 kWh
Max/Cont. Discharge Current [A] 1
200/100 (52V)
300/200 (26V)
300/300 (13V)
Max & Cont. Charge Current [A]
100 (52V)
200 (26V)
300 (13V)
Nominal Voltage [V]
Available in 13V, 26V and 52V options
Max Recommended Inverter Total Rated Power (cont.) [kVA]
8 (52V)
8 (26V)
4 (13V)
Max. Daily DoD Suggested (average)
80% DoD
265x600x330
Crated Dimensions – H x W x D [mm]
406x696x448
Battery Weight [kg]
49
Crated Weight [kg]
64
Helutherm 145 1×50 (Marine Approved)
Round Trip Efficiency [%]
96-98
Enclosure
Aluminium powder coated, tamper proof, waterproof IP65 corrosion resistant, handles or eye bolts for lifting, rubber feet. Suitable for partially protected areas away from direct sunlight and extreme moisture
Protection
Shunt Trip Circuit Breaker sized to suit max current, can be tripped by BMS if critical fault, manual reset. Protection for overcurrent, cell under and over voltage, temperature, weak cell detection and other critical events
Control Interface
CAN Bus (Note that an external relay control harness is an optional item and must be specified with the order if the application needs the battery to control relays such as for alternator regulator remote enable)
Human Interface
USB plug for programming and data access with PC, main breaker, Error Reset button, SoC display, Error light
On-board Management
Full battery management system and internal trip protection
Battery Cooling
Natural Convection (heat generation is negligible inside the battery)
0°C to +35°C
Extreme Operating Temp [°C] 4
-20°C to +60°C
Warranty 5
Standard Warranty: 10 years (or 6000 cycles) 80% DoD, 0.5C Max Discharge, 0.25C Max Charge, Max 25°C
Service Life
>16 years (>5500 cycles) expected life at 80% DoD, >20 years (>7500 cycles) at 50% DoD
Essential Accessories
Note that for connecting the battery to a PC a USB “printer” cable is required (one is supplied with each
battery) CAN Bus Termination Resistor – one required per battery (one included with battery) CAN Bus Cable (RJ45 LAN Cable) – one required per battery (not supplied with battery). Note some inverters will require a special (non-standard pin configuration) cable – see installation manual.